Vacuum
Circuit Breaker

Inside
the Cubicle
 |
Fully segregated circuit breaker compartment ensures that no
arc product or foreign body can travel from or to cable and bus bar
compartment.
|
 |
A screw type racking arrangement
for easy insertion and withdrawal of the Circuit Breaker renders perfect contact
pressure, independent of operator's force.
|
 |
A positive interlock to ensure the circuit breaker insertion
to or withdrawal from SERVICE position only when it is OPEN. |
Retrofit
(Indoor MOCB Panel)
-
Jyoti
MOCB Panel
-
Other
make MOCB Panel
Jyoti Ltd.
has successfully carried out 'Retrofitting' of nearly 1000 MOCBs
with VCBs in last decade at number of installations.
|

Retrofitting Medium
Voltage Old MOCB Switchgear with VCB
|

Rear view of
One-to-One VCB |
|
|
Bus
bars
 |
Bus
bars and jumpers are covered with special heat shrink
sleeves
which provide effective insulation between phases or
phase to earth, even if bridged by vermin or any other
conducting body. |
 |
Flexible insulating shrouds cover the
bus bar to jumper
joints and jumper to stationery contact joints |
|
|
.....
|
Automatic safety shutters cover the live parts when circuit
breaker is not in SERVICE position, for safety to operating
personnel.
 |
Independent safety shutters for upper and lower disconnect
contacts. Each independently pad lockable in open or closed
condition.
|
 |
Eproxy moulded stationary
disconnect contacts provide
effective segregation between phases and phase to earth. |
A separate segregated compartment
for voltage transformers. Voltage transformer connections through eproxy moulded
contacts.
 |
Withdraw able
voltage transformer truck arrangement.
|
 |
Automatic safety shutters cover the
live parts when voltage
transformer is withdrawn outside the crucible.
|
 |
Adequate space for entry and termination of two sets of
3-core or 6 nos. (2 per phase of single core) cable
connections. |
 |
Additional sets of cables or current transformers can be
housed within modular rear extension. |
Vacuum
Contactor - (Indoor)
 |
 |
|
Medium
Voltage Vacuum contactor |
Rear
view Vacuum contactor |
-
Suitable
for 3.3kv / 6.6kV 400 Amp.
-
A
compact , light weight construction, optimized to give minimum
weight.
-
Excellent
Choice for switching motors transformers and Capacitors.
-
Available
In two versions Electrical and Mechanicals.
-
Exceptionally
High mechanical and electrical life( In million operations)
-
Low
Chopping Current ( maximum 1.5 Amp and Avg 0.9 Amp)
-
Suitable
for High Switching frequency ( around 300 operations per hour)
-
Cheaper
/ cost saving device for motor , transformer and capacitor
switching.
-
Low
maintenance.
|
Ring
Main Unit
 |
 |
| Rear
view Main Unit |
Ring
Main Unit
(JRM Series) |
|
|
|