Pumps
|
|
LARGE PUMP TESTING BED
|
|
|
|
|
|
| |
PUMP TEST FACILITIES AT WORKS
Large Pump Testing Shop
| Sr No. |
Station |
Accuracy |
Capacity range in LPM |
Electric Power supply |
Sump Depth |
| 1. |
Rectangular Weir |
1.5% |
22000 - 111500 |
415 V (LT)
325 KW
550 A
AND
11/6.6/3.3 KV (HT) 200 A
2500 kW(Super-Imposition method of loading for temperature rise) Conforming to
IEEE 112 |
5.86 M |
| 2. |
Orifice plate |
1.5% |
83000-500000 |
8.7 M |
| 3. |
Ultrasonic flow meter |
0.5% |
Upto 15 M/sec velocity in pipe size 25 mm to 5000 mm. |
- |
| 4. |
300 dia electro magnetic flow meter. |
1.0% |
Up to 42000 |
- |
Other Facilities:
Head can be measured up to 250 MWC.
Digital test gauge is available for pressure measurement upto 6 Kg/cm2 with 0.1% accuracy.
Power analyzer for on line measurement of KW, PF, V, A available.
|
|
STANDARD PUMP TESTING BED
|
| |
 |
| |
Standard Pump Testing Shop
| Sr No. |
Station |
Accuarcy |
Capacity range in LPM |
Electric Power supply |
Sump Depth |
| 1. |
90° V - Notch |
1.5% |
134 - 7200 |
415 V (LT)
490 A
280 KW. |
5.2 M |
| 2. |
Rectangular Weir |
1.5% |
6000 - 50000 |
5.9 M |
| 3. |
Ultrasonic flow meter |
0.5% |
Upto 15 M/sec velocity in pipe size 25 mm to 5000 mm. |
- |
| 4. |
300 dia Electro magnetic flow meter. |
1.0% |
Up to 42000 |
- |
| 5. |
100 mm dia Electromagnetic flow meter |
1.0% |
Up to 4667 |
- |
Other Facilities:
Head can be measured up to 250 MWC.
Digital test gauge is available for pressure measurement upto 6 Kg/cm2 with 0.1% accuracy.
Power analyzer for on line measurement of KW, PF, V, A available.
|
| |
PUMP TESTING FACILITIES AT R&D CENTRE
|
| |
 |
| |
Flow Measurement:
Orifice Plate : Up to 40000 LPM
Venturimeter : Up to 25000 LPM
300 dia Electromagnetic flow meter : Upto 42000 LPM
100 dia Electromagnetic flow meter : Up to 4667 LPM
Head Measurement:
Digital test gauge Pressure measurement up to 6.0 Kg/cm2.
Power Measurement:
Up to 93 KW, 415 V.
Online measurement by Power Analyser for KW, PF, Volts & Ampere
|
| |
Test Facility Upgradation
|
| |
The present facility at Jyoti is well suited to cater to all pump testing
requirements in-house as well as for customer inspection.
However as an ongoing exercise Jyoti has plans for upgradation/modernization
of the test facilities.
Jyoti proposes to
modernize the model test facility at par with the best in the
world.
Jyoti also plans to upgrade the large pump test facility to cater to larger flows
as per customer’s needs , so that the pumps can be tested to actual site
conditions.
|
|
... |
|
|