Designed, Engineered,
Manu-factured and tested Largest rating Vertical Motor of rating
: 2250 kW (3000hp) 6600 Volts, 595
r.p.m. (10-Pole), Vertical - Mounting with
Closed-Air-Circuit-Air-Cooled (C.A.C.A.) for Lift - Irrigation
Schemes. Latest design techniques were used to achieve enery
efficient design combined with low-noise and vibration levels and
optimizes material content and process time. Improvement in
assembly, tolerances and clearances were achieved through latest
state-of-the-art software like Pro/Engineer. The product has
achieved success as
"FIRST-TIME-PASS" with "ZERO DEFECT". |
 |
Design
and Development of Compact class H/H brush-less Industrial
Alternators up-to 750kVA/415Volts/4 Pole for diesel engine prime-movers. |
 |
INCREASED SAFETY: Type
”e” certification from External agency for lower rating medium voltage
motors [20 H.P./2 Pole/415Volts]. |
 |
Design , Development,
Manu-facturing and Testing of Fan less Vertical Double Cage Motors for
Pump application (MIDC-14 Nos.) |
 |
Design and Development of
water-Jacket cooled 70kW/6Pole/ 200Volts/2-400Hz motors for Hybrid Electric
Vehicle [for the project of ERDC & I, Ashok Leyland Ltd and Ministry of
Information Technology - Delhi]. |
 |
Design, Development and
Approval form RDSD, of Auxiliary Motors for new Railway WAG 9 [Motors VMT,
VRH, MCP, M/c Room Blower, Oil cooler Blower, Scavenger Blower, To-Pump,
Co-Pump]. |
 |
Design and Execution of
large rating 6 MW/ 8 Pole/ 11kV Horizontal Hydel Generator for Shimsha Hydel
Project [Drawings created on Pro/Engg.]. |
 |
Design, Development,
Manu-facturing and Testing of 400 mm Thrust and Journal tilting Pad Bearing
for Hydel Application. |
 |
Micro-processor
based AVR for standard alternators upto 1000kVA. |
 |
Execution of one number
7MW/4P/11KV Water-cooled cylindrical Rotor Alternators against order, based
on Jeumont Collaboration. |
 |
Design, Development,
Manu-facturing and Testing of 800kW/6P /6.6kV/CACA motor for I.D. fan
application [For Kutch Lignite Power Station] |
 |
Design, Development,
Manu-facturing and Testing of 565kW/6P /6.6kV/CACA for F.D. fan application
[For Kutch Lignite Power Station]. |
 |
Design, Development,
Manu-facturing and Testing of 450kW/4P /6.6kV/TEFC for F.D. fan application,
for Nuclear Power Corp. (Kota Unit). |
 |
Design, Development,
Manu-facturing and Testing of Rating 6MW/12P/11kV Horizontal for Kemphole
Hydel Project. |
 |
Design, Development,
Manu-facturing and Testing of Vertical motor of Rating of
2150kW/10P /11kV/Water Cooled [For Purander Project] |
 |
Design, Development,
Manu-facturing and Testing of Marine Alternator of Rating 400kW/415V /1500RPM
with in built Water tight construction [IRS Inspecting Authority] |
 |
Design, Development,
Manu-facturing and Testing of High Efficiency [97%],low noise[70dB(A)] Larger
Rating, Vertical High Voltage Motor for Pump Application. Rating of
1320kW/14P /6.6kV/CUCW [Vijay Wada TPS] |
 |
12 kV
,25 kA, 2000 Amps full-truck vacuum circuit breaker for MOCB
replacement. |
 |
12 kV,
25 kA Magnetic Actuator-operated vacuum circuit breaker. |
 |
12 kV,
12.5 kA pole-mounted, Magnetic Actuator-operated auto-recloser. |
 |
A
range of 150 mm(6" )and 200mm (8") submersible pumps. |
 |
3HP
and 5HP open-well submersible pumps. |