| Product Range |
| |
Turbines |
Head - metres |
Output - kW |
Pelton |
150 – 700 |
50 – 10,000 |
Francis |
15 – 190 |
50 - 10,000 |
Turgo |
20 – 210 |
10 – 1,500 |
Kaplan (including Semi Kaplan and Propeller) |
3 – 30 |
500 - 10,000 |
Inlet Valves |
Size (mm) |
Butterfly Valve |
300 – 3,500 |
Spherical Valve |
400 – 600 |
Hydro Generators |
Capacity (kw) |
Synchronous / Induction LT |
10 – 1,000 |
Synchronous HT |
400 – 10,000 |
Induction HT |
400 - 5000 |
Governors |
Digital Micro Processor/ PLC Based |
|
| |
| |
 |
| |
| |
 |
| |
| |
 |
| |
| Selection
Chart : |
 |
| |
| Note : |
 |
Approx. discharge
requirement can be worked out using equation, Q = K x P/H Cumec, where K = 0.12 to 0.13 |
 |
The above
H v/s P diagram gives the application field of each type of turbine and
help in selecting the turbine type. |
 |
For overlapping
area, relative efficiency and the effect of turbine setting on the civil
cost must be considered.
|
|
| |
| |