Testing Facilities  |
| |
| LARGE PUMP TESTING BED |
|
| |
PUMP TEST FACILITIES AT WORKS
Large Pump Testing Shop |
| |
| Sr No. |
Station |
Accuracy |
Capacity range in LPM |
Electric Power supply |
Sump Depth |
| 1. |
Rectangular Weir |
1.5% |
22000 - 111500 |
415 V (LT) 325 KW
550 A
AND
11/6.6/3.3 KV (HT) 200 A
2500 kW(Super-Imposition method of loading for temperature rise) Conforming to
IEEE 112 |
5.86 M |
| 2. |
Orifice plate |
1.5% |
83000-500000 |
8.7 M |
| 3. |
Ultrasonic flow meter |
0.5% |
Upto 15 M/sec velocity in pipe size 25 mm to 5000 mm. |
- |
| 4. |
300 dia electro magnetic flow meter. |
1.0% |
Up to 42000 |
- |
|
| |
| Other Facilities: |
 |
Head can be measured up to 250 MWC. |
 |
Digital test gauge is available for pressure measurement upto 6 Kg/cm2 with 0.1% accuracy. |
 |
Power analyzer for on line measurement of KW, PF, V, A available. |
|
| |
| STANDARD PUMP TESTING BED |
|
| |
| Standard Pump Testing Shop |
| |
| Sr No. |
Station |
Accuarcy |
Capacity range in LPM |
Electric Power supply |
Sump Depth |
| 1. |
90° V - Notch |
1.5% |
134 - 7200 |
415 V (LT)
490 A
280 KW. |
5.2 M |
| 2. |
Rectangular Weir |
1.5% |
6000 - 50000 |
5.9 M |
| 3. |
Ultrasonic flow meter |
0.5% |
Upto 15 M/sec velocity in pipe size 25 mm to 5000 mm. |
- |
| 4. |
300 dia Electro magnetic flow meter. |
1.0% |
Up to 42000 |
- |
| 5. |
100 mm dia Electromagnetic flow meter |
1.0% |
Up to 4667 |
- |
|
| |
| Other Facilities: |
 |
Head can be measured up to 250 MWC. |
 |
Digital test gauge is available for pressure measurement upto 6 Kg/cm2 with 0.1% accuracy. |
 |
Power analyzer for on line measurement of KW, PF, V, A available. |
|
| |
| PUMP TESTING FACILITIES AT R&D CENTRE |
|
| |
| Flow Measurement : |
 |
Orifice Plate : Up to 40000 LPM |
 |
Venturimeter : Up to 25000 LPM |
 |
300 dia Electromagnetic flow meter : Upto 42000 LPM |
 |
100 dia Electromagnetic flow meter : Up to 4667 LPM |
|
| |
| Head Measurement : |
 |
Digital test gauge Pressure measurement up to 6.0 Kg/cm2. |
|
| |
| Power Measurement : |
 |
Up to 93 KW, 415 V. |
 |
Online measurement by Power Analyser for KW, PF, Volts & Ampere |
|
| |
| Test Facility Upgradation |
 |
The present facility at Jyoti is well suited to cater to all pump testing requirements in-house as well as for customer inspection. |
 |
However as an ongoing exercise Jyoti has plans for upgradation/modernization of the test facilities. |
 |
Jyoti proposes to
modernize the model test facility at par with the best in the world. |
 |
Jyoti also plans to upgrade the large pump test facility to cater to larger flows as per customer’s needs , so that the pumps can be tested to actual site conditions. |
|
| |