Rotating Electrical Machines - Type Test
 
Quality Plan Type Test
 
Test Conducted on Induction Motor
 
Routine Test
 
The following routine tests as per IS-325 are conducted on all motors;
 
Insulation resistance test.
Measurement of resistance of windings of stator and wound rotor.
No-Load test.
Locked rotor readings of voltage, current and power input at suitable reduced voltage.
Reduced voltage running up test (for squirrel cage motors).
Open circuit voltage ratio of stator and rotor windings (for slip ring motors).
High voltage test.
 
Type Test
 
The following Type tests as per IS-325 are carried out:
 
Measurement of resistance of windings of stator and wound rotor.
No load test at rated voltage to determine input current, power and speed. en circuit voltage
Open-circuit test of wound rotor motors.
Reduced voltage running up test at no load.
Locked rotor readings of voltage, current and power input at suitable reduced voltage.
Full load test to determine efficiency, power factor and slip.
Temperature rise test.
Momentary overload test.
Insulation resistance test.
High voltage test.
 
Additional Test
 
The following additional tests are also carried out on request :
 
Test for vibration severity of motor on no-load.
Test for noise levels of motor on no-load.
Test for degree of protection by enclosure (For second numeral only).
 
Note : Type test on vertical motors will be conducted with its respective/suitable pump coupled. Load test and temperature rise test will be conducted at maximum available load.
 
 